Model SHEATH series (Bendable Wiry Probes)
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|---|
How to order of SHEATH series
![]() ![]()
|
You can choose Form as below.
Supplementary information
The sheath tube can be coated with Teflon. A Teflon coating will improve resistance against chemicals and enable the use of the probe for measuring the temperatures of acids alkalis, food. etc. Applicable sheath diameter : φ1.0, φ1.6, φ3.2
|
|---|
Specifications
| Outside diameter (mm) | 0.25 |
0.5 |
1.0 |
1.6 |
3.2 |
4.8 |
6.4 |
8.0 |
|
| Type : K Max.temp.(°C) |
SUS316(M1) | - |
- |
650 |
650 |
750 |
800 |
800 |
900 |
| SUS310S(M2) | - |
- |
650 |
650 |
750 |
800 |
800 |
900 |
|
| Inconel(M3) | 500 |
500 |
650 |
650 |
750 |
900 |
1000 |
1050 |
|
| Type : E Max.temp.(°C) |
SUS316(M1) | - |
- |
650 |
650 |
750 |
800 |
800 |
800 |
| Response time (sec.) | 0.4 |
0.9 |
2 |
3 |
5 |
10 |
15 |
20 |
|
| Standard resistance (Ω / m) |
Type : K | 570 |
124 |
32 |
13 |
4 |
2.2 |
1.0 |
0.7 |
| Type : E | - |
- |
38 |
15 |
5 |
2.6 |
1.2 |
0.9 |
|
| Max. Length (m) | J1,J3 | 5 |
10 |
50 |
50 |
50 |
50 |
30 |
20 |
| J2 | 2 |
2 |
2 |
5 |
15 |
30 |
30 |
20 |
|
| Accuracy | Type : K | -40 to 333°C : ±2.5°C, 333 to 1200°C : ±(measuring×0.75%)°C | |||||||
| Type : E | -40 to 333°C : ±2.5°C, 333 to 900°C : ±(measuring×0.75%)°C | ||||||||